CM-60 INSTRUCTION MANUAL ULTRA
STEREO LABS, INC.
- 12 -
4. Crossover monitoring: The CM-60 also has line-level inputs
for monitoring the biamp crossovers. These connections are
available only on the DB25 connector. There are no screw
terminals. The three front channels have low and high frequency
inputs. The DSP-60 (and perhaps others) will simultaneously
transmit the full-range audio signal and the high and low
frequency crossover outputs. It may be necessary therefore to
disable the full range signal so only the post-crossover audio is
being monitored. There are jumpers inside the CM-60 for this
purpose (see pg. 13).
5. Split Surround Processors: For connection to split-surround
processors such as the Ultra
Stereo models JS-230, connect the
left and right processor outputs to the CM-60 surround left and
surround right inputs, respectively.
6. Line Output: For convenient connections to Ultra
Phonic or
other hearing impaired systems, the CM-60 has a line-level
output that combines the left, center, and right processor out-
puts.
Setting Levels
Run a pink noise test film such as Ultra
Stereo Type 1 or Dolby
®
Cat. 69. Set the processor main fader and power amplifier levels
so the house speakers are playing back at the normal listening
level. Set the Processor/Amplifier switch to Processor and note
the reading on the front panel bargraph meter. Next, set the
Processor/Amplifier switch to Amplifier, and adjust the
Amplifier Level trimpot on the rear of the unit for the same
bargraph reading.