A Network I/O Resource 15
Cinema.JNIOR Application Manual
Action – User selectable action to take when this Action is executed. There are a variety
of types of actions based upon the device to be controlled:
JNIOR I/O
Outputs – Open, Close, Toggle and Pulse (pulse duration is 1 second by default)
Inputs – “Soft Pulse” – the JNIOR creates the input ‘high’ (or ‘on’) message
without any electrical signal wired to the input. The JNIOR will send out the
message packet indicating the input has gone ‘high’ for external devices, such as a
Cinema Server, monitoring the JNIOR to use the input signal as a trigger.
JNIOR Control Panel
LEDs – the 12 LEDs on the JNIOR Control Panel are controlled via the macros.
The LEDs can be set to On, Off, Flash Slow, Flash Medium and Flash Fast
Sounds – the speaker on the JNIOR Control Panel can play various sounds
including Play Sound, Soft Alarm, Medium Alarm, Loud Alarm, Custom Alarm
and Silence Alarm
Clients
Preshow Client – action can be added to send text to the Preshow Client
Cinema Server Client – action can be added to send text to the Cinema Server
Devices
The currently available devices that can be utilized with Cinema.JNIOR are listed
in Appendix E. The RAW Ethernet and RAW Serial devices give you the ultimate
in flexibility to integrate devices regardless of whether they are built into
Cinema.JNIOR or not. For the RAW Ethernet or RAW Serial devices, the only
action available is a Send command. This will send the information entered in the
Data column to the device.
Data – Defines the pulse duration or other data to be sent to the devices listed above.