INTEG Process Group, Inc.
JNIOR
A Network I/O Resource 24
Cinema.JNIOR Application Manual
7.2 Client Configuration
Cinema.JNIOR can accept one
connection from a Client and this connection can be over
the serial port or the Ethernet port. The default is a serial connection via the AUX Serial
Port. The Method key is used to enable or disable serial communications, while the serial
port to be use is defined in the Serial Port Configuration keys (described next). The
Ethernet connection is enabled by entering a valid port number in the TcpPort key.
The Termination Strings are the characters attached at the end of each message sent by
the Client to the JNIOR or the JNIOR to the Client.
If the user wants the Client to use the Serial Commands (see Appendix B), the Serial
Commands Enabled key must be set to true. If the user wants to receive the serial
message notifying the user of input status change, the Unsolicited IO Alerts key must be
set to true and if the user wants the digital input counter values attached, the Send Counts
key must be set to true.
When the Unsolicited IO Alerts is enabled, it is recommended to disable (set to false) the
Send Ack and Send Date Stamp keys. The Send Ack message is a + or – sign included
with the message indicating it was a success (+) or denied (-). The Send Date Stamp
message is the date and time the command was executed.
The Push Button registry keys affect the operation of a push button wired to a JNIOR
input (the default input is number 7, but it can be changed by modifying the appropriate
I/O Registry Key (PreshowStartPushButtonInput).
Registry Key Default Valid Values
AppData/Cinema/Client/….
FailSafeInputTrigger -1 any input number
FailSafeTimerDuration -1 time in seconds
IncomingTerminationString \r\n \r \n
Method SERIAL Serial, disabled
OutgoingTerminationString \r\n \r \n
PushButtonDebounceDuration 45 time in seconds
PushButtonFailSafeDuration 10 time in seconds
PushButtonMacroExecute true false, true
Query false false, true